{"id":5906,"date":"2026-08-19T02:21:33","date_gmt":"2026-08-19T02:21:33","guid":{"rendered":"https:\/\/drolin-box.com\/?p=5906"},"modified":"2026-08-19T02:25:47","modified_gmt":"2026-08-19T02:25:47","slug":"lista-de-verificacion-de-los-requisitos-del-sitio-para-contenedores-de-mineria","status":"publish","type":"post","link":"https:\/\/drolin-box.com\/es_co\/mining-container-site-requirements-checklist\/","title":{"rendered":"Lista de verificaci\u00f3n de los requisitos del sitio para contenedores de miner\u00eda: energ\u00eda el\u00e9ctrica, cimientos, drenaje y acceso para la entrega"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"5906\" class=\"elementor elementor-5906\" data-elementor-post-type=\"post\">\n\t\t\t\t<div data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-element elementor-element-7b54561 e-flex e-con-boxed e-con e-parent\" data-id=\"7b54561\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f81f1e0 elementor-widget elementor-widget-text-editor\" data-id=\"f81f1e0\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p data-pm-slice=\"1 1 []\">Un terreno llano y una l\u00ednea el\u00e9ctrica cercana no hacen que un sitio minero sea apto para su instalaci\u00f3n.<\/p><p>La verdadera prueba es si el sitio puede recibir un contenedor cargado, ubicarlo de manera segura, suministrarle energ\u00eda sin sobrecargar el sistema el\u00e9ctrico, disipar el calor en el d\u00eda m\u00e1s caluroso previsto en el dise\u00f1o, drenar el agua pluvial, permitir el acceso para el mantenimiento y mantener una ruta de emergencia.<\/p><p>Si no se cumple alguna de esas condiciones, un contenedor \u201clisto para usar\u201d se convierte en un proyecto de obras civiles tras su entrega.<\/p><p>Por eso es importante confirmar los requisitos del sitio para los contenedores de miner\u00eda antes de la cotizaci\u00f3n final, y no despu\u00e9s de que el equipo llegue a la entrada. La informaci\u00f3n del sitio influye en el tama\u00f1o del transformador, la cantidad de contenedores, la configuraci\u00f3n de enfriamiento, el trazado de los cables, el dise\u00f1o de los cimientos, el m\u00e9todo de instalaci\u00f3n y el costo del proyecto.<\/p><p>Dise\u00f1a el sitio antes de pedir la caja.<\/p><h2>1. La preparaci\u00f3n del sitio comienza con la lista de mineros reales<\/h2><p>El primer paso en la preparaci\u00f3n del sitio para una granja de miner\u00eda no es medir el terreno. Es definir la carga de TI.<\/p><p>Prepara la siguiente informaci\u00f3n:<\/p><ul data-spread=\"false\"><li><p>Marca y modelo exacto de la minera<\/p><\/li><li><p>Cantidad de cada modelo<\/p><\/li><li><p>Potencia nominal y m\u00e1xima de entrada<\/p><\/li><li><p>Tensi\u00f3n de entrada requerida<\/p><\/li><li><p>Configuraci\u00f3n con enfriamiento por aire o por agua<\/p><\/li><li><p>Overclocking programado o modo de funcionamiento de alta potencia<\/p><\/li><li><p>Carga de implementaci\u00f3n inicial y carga de expansi\u00f3n futura<\/p><\/li><\/ul><p>No bases el c\u00e1lculo del proyecto \u00fanicamente en la capacidad nominal de los contenedores. Dos contenedores con las mismas dimensiones f\u00edsicas pueden tener requisitos el\u00e9ctricos y de refrigeraci\u00f3n muy diferentes si uno alberga mineros refrigerados por aire de 3,5 kW y el otro, mineros hidr\u00e1ulicos de 5 kW.<\/p><p>Usa esta f\u00f3rmula b\u00e1sica para calcular la carga:<\/p><p><strong>Carga de TI (kW) = Cantidad de mineros \u00d7 Potencia m\u00e1xima de entrada de los mineros (kW)<\/strong><\/p><p>Por lo tanto, la demanda de la instalaci\u00f3n debe incluir los equipos de refrigeraci\u00f3n, las bombas, los ventiladores, los controles, la iluminaci\u00f3n, los equipos de red y las p\u00e9rdidas por distribuci\u00f3n.<\/p><p>Si se utiliza el PUE:<\/p><p><strong>Carga de la instalaci\u00f3n (kW) = Carga de TI \u00d7 PUE de dise\u00f1o<\/strong><\/p><p>No vuelvas a agregar la carga de enfriamiento si ya est\u00e1 incluida en el modelo PUE.<\/p><h3>C\u00e1lculo ilustrativo con Transformer<\/h3><p>Supongamos que un proyecto tiene:<\/p><ul data-spread=\"false\"><li><p>300 mineros<\/p><\/li><li><p>3,5 kW de consumo m\u00e1ximo por minero<\/p><\/li><li><p>Carga de TI de 1 050 kW<\/p><\/li><li><p>1,10 PUE modelado<\/p><\/li><li><p>Factor de potencia de 0,95<\/p><\/li><li><p>Carga prevista del transformador 80%<\/p><\/li><\/ul><p>El c\u00e1lculo queda as\u00ed:<\/p><p><strong>Carga de la instalaci\u00f3n = 1 050 \u00d7 1,10 = 1 155 kW<\/strong><\/p><p><strong>kVA de operaci\u00f3n = 1 155 \u00f7 0,95 = 1 216 kVA<\/strong><\/p><p><strong>Capacidad nominal requerida = 1 216 \u00f7 0,80 = 1 520 kVA<\/strong><\/p><p>A continuaci\u00f3n, el proyecto pasar\u00eda al siguiente tama\u00f1o est\u00e1ndar de transformador adecuado, sujeto a las normas locales, la temperatura ambiente, la altitud, los estudios de arm\u00f3nicos, el an\u00e1lisis de corrientes de falla y la estrategia de redundancia seleccionada.<\/p><p>Esto es solo un ejemplo, no una recomendaci\u00f3n general sobre transformadores.<\/p><h3>Consejo de experto<\/h3><p>Para un parque de miner\u00eda de entre 3 MW y 5 MW, considera el uso de bloques el\u00e9ctricos modulares en lugar de conectar cada contenedor a un \u00fanico punto de distribuci\u00f3n de gran tama\u00f1o. Los bloques independientes de transformadores y aparatos de conmutaci\u00f3n pueden simplificar la puesta en marcha por etapas, el mantenimiento y el aislamiento de fallas.<\/p><h2>2. Verifica el suministro de la empresa de servicios p\u00fablicos antes de seleccionar el transformador<\/h2><p>No basta con que una empresa de servicios p\u00fablicos diga que la energ\u00eda est\u00e1 \u201cdisponible en las cercan\u00edas\u201d. Los compradores necesitan confirmar qu\u00e9 es lo que realmente se puede suministrar en los l\u00edmites del sitio.<\/p><p>La inspecci\u00f3n el\u00e9ctrica debe identificar:<\/p><ul data-spread=\"false\"><li><p>Capacidad confirmada de la empresa de servicios p\u00fablicos<\/p><\/li><li><p>Fecha de conexi\u00f3n a la red<\/p><\/li><li><p>Tensi\u00f3n y frecuencia de alimentaci\u00f3n<\/p><\/li><li><p>Corriente de cortocircuito disponible<\/p><\/li><li><p>L\u00edmite de propiedad del transformador<\/p><\/li><li><p>Requisitos de medici\u00f3n<\/p><\/li><li><p>M\u00e9todo de conexi\u00f3n a tierra<\/p><\/li><li><p>Requisitos de coordinaci\u00f3n en materia de protecci\u00f3n<\/p><\/li><li><p>Restricciones de demanda m\u00e1xima<\/p><\/li><li><p>Capacidad de expansi\u00f3n<\/p><\/li><li><p>Requisitos de generadores o de energ\u00eda de respaldo<\/p><\/li><\/ul><p>El dimensionamiento de un transformador no consiste simplemente en sumar la carga de TI a un porcentaje fijo. El ingeniero debe tomar en cuenta el factor de potencia, la carga continua, el contenido arm\u00f3nico, la temperatura ambiente, la altitud, la expansi\u00f3n futura y las consecuencias de la p\u00e9rdida de un transformador.<\/p><p>La gran altitud merece una atenci\u00f3n especial. La menor densidad del aire reduce el rendimiento de enfriamiento de los equipos el\u00e9ctricos refrigerados por aire. Schneider Electric, por ejemplo, publica un m\u00e9todo de reducci\u00f3n de potencia por altitud para ciertos transformadores de bajo voltaje de tipo seco a m\u00e1s de 1,000 metros. Esto no se aplica autom\u00e1ticamente a todos los transformadores, pero demuestra por qu\u00e9 es necesario verificar la curva de altitud del proveedor.<\/p><p>El mismo problema afecta a los mineros. BITMAIN indica que el S21 puede funcionar a una altitud de hasta 2,000 metros y se\u00f1ala que, entre los 900 y los 2,000 metros, su temperatura m\u00e1xima de funcionamiento disminuye a medida que aumenta la altitud.<\/p><p>La decisi\u00f3n pr\u00e1ctica es clara: la altitud debe incluirse en la solicitud de cotizaci\u00f3n.<\/p><h2>3. La temperatura, la humedad y la altitud influyen en el dise\u00f1o del sistema de refrigeraci\u00f3n<\/h2><p>\u201cLa \u201dtemperatura media anual\u00bb no es, por s\u00ed sola, un valor de dise\u00f1o \u00fatil.<\/p><p>El sistema de enfriamiento debe evaluarse en funci\u00f3n de:<\/p><ul data-spread=\"false\"><li><p>Temperatura m\u00e1xima de bulbo seco<\/p><\/li><li><p>Temperatura m\u00e1xima del bulbo h\u00famedo<\/p><\/li><li><p>Rango de temperatura diario<\/p><\/li><li><p>Temperatura m\u00ednima estacional<\/p><\/li><li><p>Humedad relativa<\/p><\/li><li><p>Punto de roc\u00edo<\/p><\/li><li><p>Exposici\u00f3n al polvo y a la arena<\/p><\/li><li><p>Lluvia y nieve<\/p><\/li><li><p>Niebla salina o aire corrosivo<\/p><\/li><li><p>Direcci\u00f3n predominante del viento<\/p><\/li><li><p>Altitud del lugar<\/p><\/li><\/ul><p>A modo de referencia, BITMAIN especifica una temperatura de funcionamiento de 0 \u00b0C a 45 \u00b0C y una humedad relativa sin condensaci\u00f3n de 10% a 90% para el modelo S21. Otros modelos de mineros tienen l\u00edmites diferentes.<\/p><p>Un sitio que alcance los 43 \u00b0C podr\u00eda parecer que se mantiene dentro de ese rango. Sin embargo, el contenedor a\u00fan necesita un margen de temperatura suficiente para compensar la restricci\u00f3n de entrada de aire, los filtros sucios, la recirculaci\u00f3n de aire caliente y el flujo de aire desigual.<\/p><p>Dise\u00f1ado para el filtro sucio y la tarde m\u00e1s calurosa.<\/p><p>La humedad plantea un riesgo distinto. Una humedad relativa elevada no constituye autom\u00e1ticamente una condici\u00f3n de falla, pero la condensaci\u00f3n s\u00ed lo es. Las tuber\u00edas fr\u00edas, los colectores o las conexiones del l\u00edquido refrigerante pueden alcanzar temperaturas inferiores al punto de roc\u00edo local, lo que provoca la formaci\u00f3n de humedad cerca de los equipos el\u00e9ctricos.<\/p><p>En el caso de los mineros hidr\u00e1ulicos, la preparaci\u00f3n del sitio tambi\u00e9n debe ajustarse a los requisitos de refrigeraci\u00f3n del minero. Las especificaciones publicadas por BITMAIN para el modelo S21 Hyd., por ejemplo, indican lo siguiente:<\/p><ul data-spread=\"false\"><li><p>Entrada trif\u00e1sica de 380 V a 415 V<\/p><\/li><li><p>Temperatura del agua de entrada en funci\u00f3n del modo<\/p><\/li><li><p>Caudal de agua de 8 a 10 L\/min por minero<\/p><\/li><li><p>Presi\u00f3n m\u00e1xima del agua de 3,5 bar<\/p><\/li><li><p>Requisitos definidos para el fluido de trabajo y la calidad del agua<\/p><\/li><\/ul><p>Estos valores son espec\u00edficos de cada modelo. Explican por qu\u00e9 la informaci\u00f3n \u201c192 mineros hidr\u00e1ulicos\u201d no es suficiente para dise\u00f1ar la red de tuber\u00edas de la planta.<\/p><h3>Requisitos para climas fr\u00edos<\/h3><p>Una instalaci\u00f3n con enfriamiento por l\u00edquido en un clima g\u00e9lido podr\u00eda requerir:<\/p><ul data-spread=\"false\"><li><p>Concentraci\u00f3n de glicol autorizada<\/p><\/li><li><p>Tuber\u00edas exteriores protegidas contra las heladas<\/p><\/li><li><p>Instalaci\u00f3n de cables calefactores donde sea necesario<\/p><\/li><li><p>Drenajes en el punto m\u00e1s bajo<\/p><\/li><li><p>V\u00e1lvulas y colectores aislados<\/p><\/li><li><p>Un procedimiento controlado de apagado y drenaje<\/p><\/li><li><p>Controles de enfriadores secos para condiciones ambientales bajas<\/p><\/li><\/ul><p>Los contenedores refrigerados por aire tambi\u00e9n requieren una planificaci\u00f3n para climas fr\u00edos. La acumulaci\u00f3n de nieve, la nieve arrastrada por el viento, la formaci\u00f3n de hielo y el aire de entrada excesivamente fr\u00edo pueden interrumpir el flujo de aire o hacer que el equipo opere fuera de los l\u00edmites recomendados.<\/p><h2>4. La base debe soportar cargas puntuales, no solo el peso total<\/h2><p>Un contenedor de miner\u00eda no es una carga de almac\u00e9n distribuida de manera uniforme.<\/p><p>Su peso se transmite a trav\u00e9s de rieles estructurales, puntos de apoyo o piezas de esquina. Una cimentaci\u00f3n puede tener suficiente capacidad portante total y, aun as\u00ed, deformarse si los puntos de apoyo est\u00e1n mal ubicados.<\/p><p>Un ingeniero estructural o civil calificado debe confirmar lo siguiente:<\/p><ul data-spread=\"false\"><li><p>Peso operativo del contenedor<\/p><\/li><li><p>Peso de env\u00edo<\/p><\/li><li><p>Reacciones en los puntos de apoyo<\/p><\/li><li><p>Capacidad portante del suelo<\/p><\/li><li><p>Riesgo de liquidaci\u00f3n<\/p><\/li><li><p>Profundidad de congelaci\u00f3n<\/p><\/li><li><p>Condiciones s\u00edsmicas<\/p><\/li><li><p>Cargas de viento y de levantamiento<\/p><\/li><li><p>Vibraci\u00f3n de los equipos<\/p><\/li><li><p>Normas locales sobre concreto y armaduras<\/p><\/li><li><p>M\u00e9todo de anclaje requerido<\/p><\/li><li><p>Tolerancia de elevaci\u00f3n y nivelaci\u00f3n del acabado<\/p><\/li><\/ul><p>Entre los acuerdos de fundaci\u00f3n m\u00e1s comunes se encuentran:<\/p><ul data-spread=\"false\"><li><p>Una losa continua de concreto armado<\/p><\/li><li><p>Vigas de cimentaci\u00f3n reforzadas<\/p><\/li><li><p>Pilares de concreto aislados<\/p><\/li><li><p>Cimientos en esquina unidos por vigas estructurales<\/p><\/li><\/ul><p>La opci\u00f3n correcta depende de la estructura del contenedor, el informe del suelo y el clima local. No se debe copiar el espesor universal de la losa de otro proyecto.<\/p><p>La almohadilla tambi\u00e9n debe ofrecer espacio suficiente para:<\/p><ul data-spread=\"false\"><li><p>Apertura de la puerta<\/p><\/li><li><p>Acceso al panel el\u00e9ctrico<\/p><\/li><li><p>Reemplazo del filtro<\/p><\/li><li><p>Mantenimiento del ventilador<\/p><\/li><li><p>Servicio de tuber\u00edas y v\u00e1lvulas<\/p><\/li><li><p>Salida de emergencia<\/p><\/li><li><p>Retiro seguro de los mineros o las bombas<\/p><\/li><\/ul><p>En Estados Unidos, la OSHA exige que haya suficiente acceso y espacio de trabajo alrededor de los equipos el\u00e9ctricos. Para ciertos equipos que operan a 600 V o menos, la norma tambi\u00e9n exige que el ancho del espacio de trabajo sea de al menos 762 mm o el ancho del equipo, lo que sea mayor, y que haya suficiente espacio libre para que las puertas se puedan abrir al menos 90 grados. Otros pa\u00edses tienen sus propios requisitos.<\/p><p>No utilices este valor de EE. UU. como una regla de dise\u00f1o universal. \u00dasalo como un recordatorio de que el espacio destinado al servicio el\u00e9ctrico no puede convertirse en espacio de almacenamiento.<\/p><h3>Consejo de experto<\/h3><p>P\u00eddele al proveedor del contenedor un plano de la interfaz con los cimientos antes de verter el concreto. El plano debe mostrar la huella, los puntos de apoyo, el peso operativo, las ubicaciones de las entradas de cables, las interfaces de tuber\u00edas, el sentido de apertura de las puertas y las zonas de mantenimiento.<\/p><h2>5. El drenaje es parte de la confiabilidad el\u00e9ctrica<\/h2><p>La plataforma terminada no debe quedar en el punto m\u00e1s bajo del terreno.<\/p><p>La nivelaci\u00f3n del terreno debe alejar el agua de lluvia de:<\/p><ul data-spread=\"false\"><li><p>Puertas de contenedores<\/p><\/li><li><p>Gabinetes el\u00e9ctricos<\/p><\/li><li><p>Almohadillas para transformadores<\/p><\/li><li><p>Zanjas para cables<\/p><\/li><li><p>Fundamentos de la CDU<\/p><\/li><li><p>Estaciones de bombeo<\/p><\/li><li><p>Soportes para enfriadores secos<\/p><\/li><\/ul><p>El plan de drenaje del sitio debe abordar lo siguiente:<\/p><ul data-spread=\"false\"><li><p>Elevaci\u00f3n de la plataforma terminada<\/p><\/li><li><p>Pendiente de la superficie<\/p><\/li><li><p>Canaletas de drenaje<\/p><\/li><li><p>Alcanzas y canales de escurrimiento<\/p><\/li><li><p>Episodios de lluvias extremas<\/p><\/li><li><p>Descongelamiento de la nieve<\/p><\/li><li><p>Control de la erosi\u00f3n<\/p><\/li><li><p>Control de sedimentos<\/p><\/li><li><p>Contenci\u00f3n de derrames de l\u00edquido refrigerante<\/p><\/li><li><p>Separaci\u00f3n entre las aguas pluviales y el drenaje de proceso<\/p><\/li><\/ul><p>El agua estancada alrededor de los cables subterr\u00e1neos, las conexiones a tierra y los cimientos de los equipos genera problemas de mantenimiento y seguridad. Adem\u00e1s, puede dificultar el paso de los veh\u00edculos de servicio despu\u00e9s de lluvias intensas.<\/p><p>En el caso de los proyectos en Estados Unidos, las aguas pluviales industriales o la escorrent\u00eda relacionada con la construcci\u00f3n pueden estar sujetas a requisitos de permisos federales, estatales o locales. Las directrices de la EPA se\u00f1alan que la escorrent\u00eda puede acumular contaminantes procedentes de actividades industriales a la vista y que muchos programas de permisos son administrados por cada estado por separado.<\/p><p>Por lo tanto, el dise\u00f1o adecuado del sistema de drenaje es tanto una decisi\u00f3n de ingenier\u00eda como una decisi\u00f3n relacionada con la obtenci\u00f3n de permisos.<\/p><h2>6. Mantener el acceso para los bomberos y el aislamiento de emergencia<\/h2><p>Un dise\u00f1o de sitio con alta densidad puede mejorar el aprovechamiento del terreno, pero al mismo tiempo hacer que la respuesta ante emergencias sea casi imposible.<\/p><p>Antes de fijar el dise\u00f1o del sitio del contenedor de extracci\u00f3n, confirma lo siguiente:<\/p><ul data-spread=\"false\"><li><p>Acceso para camiones de bomberos<\/p><\/li><li><p>Espacio para que los veh\u00edculos de emergencia den la vuelta<\/p><\/li><li><p>Requisitos de separaci\u00f3n de contenedores<\/p><\/li><li><p>Acceso a los interruptores de desconexi\u00f3n el\u00e9ctrica<\/p><\/li><li><p>Ubicaciones de las paradas de emergencia<\/p><\/li><li><p>V\u00edas de evacuaci\u00f3n para el personal<\/p><\/li><li><p>Controles de materiales combustibles<\/p><\/li><li><p>Requisitos relativos al agua contra incendios o a los sistemas de extinci\u00f3n<\/p><\/li><li><p>Separaci\u00f3n y contenci\u00f3n de transformadores<\/p><\/li><li><p>Restricciones locales en materia de ruido y l\u00edmites territoriales<\/p><\/li><\/ul><p>La autoridad local de bomberos o la autoridad competente debe aprobar las distancias de seguridad aplicables y el plan de acceso de emergencia.<\/p><p>No coloques tuber\u00edas fijas, cables temporales ni veh\u00edculos estacionados en el carril de emergencia. Un recorrido despejado en el plano no sirve de nada si est\u00e1 bloqueado durante la operaci\u00f3n.<\/p><h2>7. Recorra toda la ruta de entrega<\/h2><p>La ruta de entrega no comienza en la entrada del proyecto. Comienza en el puerto, el dep\u00f3sito o el enlace con la carretera regional.<\/p><p>Un estudio de ruta debe verificar lo siguiente:<\/p><ul data-spread=\"false\"><li><p>Dimensiones legales de los veh\u00edculos y los contenedores cargados<\/p><\/li><li><p>L\u00edmites de peso por eje y peso bruto<\/p><\/li><li><p>Requisitos para obtener permisos para veh\u00edculos de dimensiones o peso excesivos<\/p><\/li><li><p>Capacidad de puentes y alcantarillas<\/p><\/li><li><p>Resistencia de la superficie de la carretera<\/p><\/li><li><p>Ancho de la puerta<\/p><\/li><li><p>Altura libre<\/p><\/li><li><p>L\u00edneas a\u00e9reas de energ\u00eda el\u00e9ctrica y de comunicaciones<\/p><\/li><li><p>Cruces ferroviarios<\/p><\/li><li><p>Pendientes de las carreteras<\/p><\/li><li><p>Cruces estrechos<\/p><\/li><li><p>Curvas en zigzag<\/p><\/li><li><p>Trayectoria de desplazamiento de un cami\u00f3n con remolque<\/p><\/li><li><p>Restricciones viales estacionales<\/p><\/li><li><p>Espacio para dar marcha atr\u00e1s y maniobrar<\/p><\/li><\/ul><p>No apruebes el acceso bas\u00e1ndote \u00fanicamente en el ancho de la carretera. Un cami\u00f3n con remolque largo puede entrar por una entrada recta y, aun as\u00ed, no poder tomar el giro final de 90 grados.<\/p><p>En Estados Unidos, las normas sobre el tama\u00f1o y el peso de los camiones var\u00edan seg\u00fan el estado, y los transportes de dimensiones o peso excesivos pueden requerir permisos emitidos por el estado. La recopilaci\u00f3n de la FHWA tambi\u00e9n hace hincapi\u00e9 en las dimensiones, las cargas por eje y las restricciones espec\u00edficas de cada ruta.<\/p><p>En el caso de los proyectos en el extranjero, se aplica el mismo principio: verificar todas las jurisdicciones entre el puerto de llegada y la obra de cimentaci\u00f3n.<\/p><p>Sigue las normas siempre que sea posible. De todos modos, revisa todo.<\/p><h2>8. Planifica la elevaci\u00f3n con gr\u00faa antes de que llegue el contenedor<\/h2><p>La empresa contratada para el manejo con gr\u00faa necesita saber algo m\u00e1s que el peso total del contenedor.<\/p><p>El plan de ascensor debe incluir:<\/p><ul data-spread=\"false\"><li><p>Peso de elevaci\u00f3n certificado<\/p><\/li><li><p>Centro de gravedad<\/p><\/li><li><p>Puntos de elevaci\u00f3n<\/p><\/li><li><p>M\u00e9todo de montaje<\/p><\/li><li><p>Radio de la gr\u00faa<\/p><\/li><li><p>Configuraci\u00f3n de la pluma<\/p><\/li><li><p>L\u00edmites del viento<\/p><\/li><li><p>Presi\u00f3n sobre el suelo<\/p><\/li><li><p>Ubicaciones de Outrigger<\/p><\/li><li><p>Dise\u00f1o de la plataforma de estabilizadores<\/p><\/li><li><p>Zona de exclusi\u00f3n<\/p><\/li><li><p>M\u00e9todo de localizaci\u00f3n y comunicaci\u00f3n<\/p><\/li><li><p>Distancia de seguridad con las l\u00edneas el\u00e9ctricas a\u00e9reas<\/p><\/li><li><p>Orientaci\u00f3n final en la plataforma de lanzamiento<\/p><\/li><\/ul><p>La capacidad de la gr\u00faa disminuye a medida que aumenta el radio de trabajo. Es posible que una gr\u00faa que pueda levantar el contenedor cerca de su chasis no tenga suficiente capacidad cuando se vea obligada a situarse m\u00e1s lejos debido a que no se puede acceder a la plataforma de apoyo.<\/p><p>Las l\u00edneas el\u00e9ctricas a\u00e9reas constituyen una restricci\u00f3n cr\u00edtica. De acuerdo con las normas de construcci\u00f3n de la OSHA de EE. UU., si la gr\u00faa, el cable de carga o la carga pudieran acercarse a menos de 20 pies de una l\u00ednea el\u00e9ctrica, el empleador debe seguir el procedimiento requerido de desenergizaci\u00f3n, de distancia de seguridad de 20 pies o el procedimiento de la Tabla A basado en el voltaje.<\/p><p>Las normas locales sobre elevaci\u00f3n pueden variar, pero la lecci\u00f3n de planificaci\u00f3n es universal: localiza las l\u00edneas el\u00e9ctricas antes de contratar la gr\u00faa.<\/p><h3>Consejo de experto<\/h3><p>Env\u00eda al contratista de la gr\u00faa el plano final del sitio, el peso del contenedor, el plano de los puntos de elevaci\u00f3n y las dimensiones del cami\u00f3n de entrega. Un mensaje telef\u00f3nico que diga \u201cun contenedor de 40 pies\u201d no constituye un plan de elevaci\u00f3n.<\/p><h2>9. Las instalaciones con enfriamiento por aire y las de enfriamiento por l\u00edquido requieren un espacio diferente<\/h2><p>La base del contenedor minero puede parecer similar, pero la infraestructura que la rodea no lo es.<\/p><table><tbody><tr><th>Requisitos del sitio<\/th><th>Contenedor refrigerado por aire<\/th><th>Contenedor refrigerado por l\u00edquido<\/th><\/tr><tr><td>Circuito t\u00e9rmico primario<\/td><td>Aire exterior a trav\u00e9s de los mineros<\/td><td>Circuito de refrigeraci\u00f3n hacia la CDU y descarga de calor<\/td><\/tr><tr><td>Espacio externo cr\u00edtico<\/td><td>Admisi\u00f3n y escape sin obstrucciones<\/td><td>CDU, bombas, tuber\u00edas y enfriador seco<\/td><\/tr><tr><td>Riesgo clim\u00e1tico principal<\/td><td>Polvo, calor, nieve y recirculaci\u00f3n<\/td><td>Congelaci\u00f3n, calidad del agua y temperatura de entrada<\/td><\/tr><tr><td>Interfaces principales<\/td><td>Alimentaci\u00f3n, red, admisi\u00f3n y escape<\/td><td>Tubos de energ\u00eda, red, suministro y retorno<\/td><\/tr><tr><td>Prioridad de mantenimiento<\/td><td>Limpieza de filtros, ventiladores y mineros<\/td><td>Bombas, filtros, v\u00e1lvulas y calidad del l\u00edquido refrigerante<\/td><\/tr><tr><td>Riesgo de dise\u00f1o<\/td><td>Los gases de escape entran en otra toma de aire<\/td><td>Longitud excesiva de las tuber\u00edas o desequilibrio hidr\u00e1ulico<\/td><\/tr><tr><td>Equipo externo<\/td><td>Transformadores y equipos de conmutaci\u00f3n<\/td><td>Transformadores, aparatos de conmutaci\u00f3n, CDU y enfriador seco<\/td><\/tr><\/tbody><\/table><h3>Preparaci\u00f3n del sitio para contenedores de miner\u00eda refrigerados por aire<\/h3><p>Un contenedor refrigerado por aire necesita un recorrido controlado para el aire de entrada y de salida.<\/p><p>Verifica:<\/p><ul data-spread=\"false\"><li><p>Direcci\u00f3n predominante del viento<\/p><\/li><li><p>Distancia a las paredes y a los contenedores adyacentes<\/p><\/li><li><p>Riesgo de recirculaci\u00f3n de aire caliente<\/p><\/li><li><p>Acceso a la pantalla antipolvo<\/p><\/li><li><p>Espacio para la extracci\u00f3n del filtro<\/p><\/li><li><p>Direcci\u00f3n del ruido del escape<\/p><\/li><li><p>Obstrucci\u00f3n por nieve o vegetaci\u00f3n<\/p><\/li><li><p>Espacio para el mantenimiento del ventilador<\/p><\/li><\/ul><p>Colocar dos contenedores muy cerca uno del otro puede mejorar la densidad, al tiempo que permite que los gases de escape de un contenedor entren en la toma de aire del siguiente.<\/p><p>Eso no es densidad. Es calor reciclado.<\/p><h3>Preparaci\u00f3n del sitio para un contenedor de miner\u00eda con enfriamiento por l\u00edquido<\/h3><p>Un sistema de enfriamiento por l\u00edquido requiere espacio para toda la cadena de disipaci\u00f3n de calor:<\/p><p><strong>Miner \u2192 Colector interno \u2192 CDU \u2192 Circuito externo \u2192 Enfriador seco<\/strong><\/p><p>Confirmar:<\/p><ul data-spread=\"false\"><li><p>Ubicaci\u00f3n de la CDU<\/p><\/li><li><p>Cimientos del enfriador seco<\/p><\/li><li><p>Trayecto de las tuber\u00edas de suministro y retorno<\/p><\/li><li><p>Di\u00e1metro y material de la tuber\u00eda<\/p><\/li><li><p>Caudal y presi\u00f3n de dise\u00f1o<\/p><\/li><li><p>Norma de bridas o acoplamientos<\/p><\/li><li><p>Dep\u00f3sito de expansi\u00f3n<\/p><\/li><li><p>Rejillas de ventilaci\u00f3n<\/p><\/li><li><p>Drenajes en el punto m\u00e1s bajo<\/p><\/li><li><p>Filtros y tratamiento de agua<\/p><\/li><li><p>Alimentaci\u00f3n el\u00e9ctrica de la bomba<\/p><\/li><li><p>Protecci\u00f3n contra el hielo<\/p><\/li><li><p>Detecci\u00f3n de fugas<\/p><\/li><li><p>Acceso para mantenimiento alrededor de v\u00e1lvulas e intercambiadores de calor<\/p><\/li><\/ul><p>Una cotizaci\u00f3n breve para un contenedor puede ocultar un gran volumen de trabajo de tuber\u00edas en el sitio. Define los l\u00edmites de la bater\u00eda antes de comparar precios.<\/p><h2>10. Congelar todas las interfaces antes de la fabricaci\u00f3n<\/h2><p>Muchos retrasos en la puesta en marcha se deben a peque\u00f1as incompatibilidades de interfaz:<\/p><ul data-spread=\"false\"><li><p>La instalaci\u00f3n suministra 480 V, pero el equipo requiere otra tensi\u00f3n.<\/p><\/li><li><p>El cable es demasiado grande para la placa de prensaestopas seleccionada.<\/p><\/li><li><p>Las tomas de la PDU no son compatibles con los cables de alimentaci\u00f3n del minero.<\/p><\/li><li><p>Las tuber\u00edas de suministro y de retorno est\u00e1n invertidas.<\/p><\/li><li><p>Las normas relativas a las bridas son diferentes.<\/p><\/li><li><p>El sistema de control no cuenta con un protocolo de comunicaci\u00f3n establecido.<\/p><\/li><li><p>El gabinete de red no cuenta con ning\u00fan punto de terminaci\u00f3n de fibra \u00f3ptica.<\/p><\/li><li><p>El concreto se vierte antes de que se confirme el trazado del cable subterr\u00e1neo.<\/p><\/li><\/ul><p>Elabora un cronograma de interfaces que incluya:<\/p><h3>Interfaces el\u00e9ctricas<\/h3><ul data-spread=\"false\"><li><p>Tensi\u00f3n y frecuencia de la red el\u00e9ctrica<\/p><\/li><li><p>Tensi\u00f3n secundaria del transformador<\/p><\/li><li><p>Capacidad nominal del tablero principal<\/p><\/li><li><p>Cantidad y potencia nominal de las PDU<\/p><\/li><li><p>Tama\u00f1o del cable y material del conductor<\/p><\/li><li><p>Direcci\u00f3n de entrada del cable<\/p><\/li><li><p>Dimensiones de la placa glandular<\/p><\/li><li><p>Puesta a tierra y conexi\u00f3n a masa<\/p><\/li><li><p>Circuito de parada de emergencia<\/p><\/li><li><p>Energ\u00eda auxiliar<\/p><\/li><li><p>Capacidad de cortocircuito<\/p><\/li><li><p>Configuraci\u00f3n de protecci\u00f3n<\/p><\/li><\/ul><h3>Interfaces de enfriamiento por l\u00edquido<\/h3><ul data-spread=\"false\"><li><p>Temperatura de salida y de retorno<\/p><\/li><li><p>Flujo de dise\u00f1o<\/p><\/li><li><p>Presi\u00f3n m\u00e1xima<\/p><\/li><li><p>Di\u00e1metro de la tuber\u00eda<\/p><\/li><li><p>Material de las tuber\u00edas<\/p><\/li><li><p>Norma de bridas o acoplamientos<\/p><\/li><li><p>Fluido de trabajo<\/p><\/li><li><p>Requisitos de calidad del agua<\/p><\/li><li><p>Conexi\u00f3n de llenado y drenaje<\/p><\/li><li><p>Salida de aire<\/p><\/li><li><p>Control de expansi\u00f3n<\/p><\/li><li><p>Detecci\u00f3n de fugas<\/p><\/li><li><p>Se\u00f1ales de control de la CDU y del enfriador seco<\/p><\/li><\/ul><h3>Interfaces de comunicaci\u00f3n<\/h3><ul data-spread=\"false\"><li><p>Conexi\u00f3n por fibra \u00f3ptica o Ethernet<\/p><\/li><li><p>Ubicaci\u00f3n del gabinete de red<\/p><\/li><li><p>Plan de direcciones IP<\/p><\/li><li><p>Protocolo PLC<\/p><\/li><li><p>Plataforma de monitoreo remoto<\/p><\/li><li><p>Contactos de alarma<\/p><\/li><li><p>Sensores ambientales<\/p><\/li><li><p>Requisitos de control de acceso<\/p><\/li><\/ul><p>Un programa de interfaces firmado puede evitar semanas de trabajo adicional en la obra.<\/p><h2>11. Lista de verificaci\u00f3n de los requisitos del sitio para contenedores de miner\u00eda<\/h2><p>Utilice esta lista de verificaci\u00f3n antes de aprobar la cotizaci\u00f3n final.<\/p><h3>Informaci\u00f3n del proyecto<\/h3><ul data-spread=\"false\"><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Pa\u00eds del proyecto y ubicaci\u00f3n exacta<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Coordenadas del sitio<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Modelos y cantidades de Miner<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Carga de TI inicial y futura<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Fecha de puesta en servicio requerida<\/p><\/div><\/li><\/ul><h3>Sistema el\u00e9ctrico<\/h3><ul data-spread=\"false\"><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Capacidad de servicio confirmada por escrito<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Se han confirmado el voltaje y la frecuencia de alimentaci\u00f3n<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Se ha completado el c\u00e1lculo del tama\u00f1o del transformador<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Se ha verificado la reducci\u00f3n de potencia por condiciones ambientales y altitud<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Estudio previsto sobre cortocircuitos y protecci\u00f3n<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Se han confirmado las interfaces de los tableros de distribuci\u00f3n y las PDU<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Se han confirmado el trazado del cable y los puntos de entrada del cable<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Se ha completado el dise\u00f1o del sistema de puesta a tierra<\/p><\/div><\/li><\/ul><h3>Clima y refrigeraci\u00f3n<\/h3><ul data-spread=\"false\"><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Temperaturas m\u00e1ximas y m\u00ednimas<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Humedad relativa y punto de roc\u00edo<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Altitud<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Exposici\u00f3n al polvo, la arena, la nieve o la sal<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Direcci\u00f3n predominante del viento<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Se han confirmado las zonas de entrada y salida de aire<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Se confirman las ubicaciones de las unidades CDU y los enfriadores secos<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>M\u00e9todo de protecci\u00f3n contra el congelamiento seleccionado<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Se han confirmado los requisitos relativos al l\u00edquido refrigerante y a la calidad del agua<\/p><\/div><\/li><\/ul><h3>Obras civiles<\/h3><ul data-spread=\"false\"><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Informaci\u00f3n geot\u00e9cnica disponible<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Se aprob\u00f3 el dise\u00f1o de los cimientos<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Se han confirmado los puntos de apoyo del contenedor<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Se ha confirmado el dise\u00f1o del anclaje<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Se ha establecido el nivel de terminaci\u00f3n<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Se ha completado el sistema de drenaje y las v\u00edas de escorrent\u00eda<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Zanjas para cables y manguitos para tuber\u00edas coordinados<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Se mantienen las distancias de mantenimiento<\/p><\/div><\/li><\/ul><h3>Log\u00edstica e instalaci\u00f3n<\/h3><ul data-spread=\"false\"><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Se ha inspeccionado la ruta del puerto al sitio<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Se verificaron el ancho y la altura de la puerta<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Se verific\u00f3 la capacidad de los puentes y alcantarillas<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Simulaci\u00f3n de la trayectoria final del giro<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>\u00c1rea de preparaci\u00f3n de env\u00edos disponible<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Se aprob\u00f3 la posici\u00f3n de la gr\u00faa<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Se ha verificado la presi\u00f3n sobre el suelo<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Se identificaron l\u00edneas el\u00e9ctricas a\u00e9reas<\/p><\/div><\/li><li data-task-list-item=\"true\" data-checked=\"false\"><span class=\"task-list-item-checkbox\" contenteditable=\"false\"><input tabindex=\"-1\" type=\"checkbox\" \/><\/span><div class=\"task-list-item-content\"><p>Se ha conservado el acceso para bomberos y emergencias<\/p><\/div><\/li><\/ul><h2>Errores comunes en la preparaci\u00f3n del terreno<\/h2><p>Los errores m\u00e1s costosos en los sitios web suelen ser predecibles:<\/p><ol start=\"1\" data-spread=\"false\"><li><p>Calcular la potencia del transformador bas\u00e1ndose en la potencia promedio de los mineros, en lugar de en la demanda m\u00e1xima del proyecto.<\/p><\/li><li><p>Verter los cimientos antes de recibir el plano de interfaz del equipo.<\/p><\/li><li><p>Utilizar la temperatura promedio anual en lugar de la condici\u00f3n de dise\u00f1o m\u00e1s calurosa.<\/p><\/li><li><p>Sin tomar en cuenta la reducci\u00f3n de potencia por altitud.<\/p><\/li><li><p>Medir la entrada, pero sin simular el giro del cami\u00f3n con remolque.<\/p><\/li><li><p>Reservar una gr\u00faa sin verificar el radio de trabajo y la capacidad de carga del terreno.<\/p><\/li><li><p>Colocar los contenedores refrigerados por aire de manera que los gases de escape puedan volver a la entrada de aire.<\/p><\/li><li><p>Instalaci\u00f3n de un enfriador seco sin espacio para las tuber\u00edas ni para el mantenimiento.<\/p><\/li><li><p>Considerar el drenaje de aguas pluviales como parte del paisajismo.<\/p><\/li><li><p>Permitir que los cables, las tuber\u00edas o los equipos bloqueen la ruta de emergencia.<\/p><\/li><\/ol><p>Cada error resulta m\u00e1s barato corregirlo en un plano que en el sitio de la obra.<\/p><h2>Qu\u00e9 enviar a DroLinBox antes de la planificaci\u00f3n del sitio<\/h2><p>Para recibir una revisi\u00f3n preliminar de la configuraci\u00f3n de los contenedores de extracci\u00f3n y del dise\u00f1o del sitio, env\u00ede:<\/p><ul data-spread=\"false\"><li><p><strong>Pa\u00eds y ubicaci\u00f3n del proyecto<\/strong><\/p><\/li><li><p><strong>Capacidad de potencia disponible<\/strong><\/p><\/li><li><p><strong>Modelo y cantidad del Miner<\/strong><\/p><\/li><li><p><strong>Temperatura m\u00e1xima del sitio<\/strong><\/p><\/li><li><p><strong>Temperatura m\u00ednima en el lugar<\/strong><\/p><\/li><li><p><strong>Altitud del lugar<\/strong><\/p><\/li><li><p><strong>M\u00e9todo de enfriamiento preferido<\/strong><\/p><\/li><li><p><strong>Fecha prevista de implementaci\u00f3n<\/strong><\/p><\/li><li><p><strong>Fotograf\u00edas del lugar<\/strong><\/p><\/li><li><p><strong>Plano del sitio, imagen satelital o plano de distribuci\u00f3n disponible<\/strong><\/p><\/li><\/ul><p>Si est\u00e1 disponible, proporcione tambi\u00e9n el diagrama unifilar de la red el\u00e9ctrica, la informaci\u00f3n sobre el transformador, fotograf\u00edas del acceso por carretera y la distancia entre el \u00e1rea prevista para los contenedores y el punto de conexi\u00f3n el\u00e9ctrica.<\/p><p>Usa el <a href=\"https:\/\/drolin-box.com\/en\/mining-container-quote-checklist\/\">Lista de verificaci\u00f3n para cotizaciones de contenedores para miner\u00eda<\/a> para preparar sus aportaciones comerciales y t\u00e9cnicas.<\/p><p>Revisa el <a href=\"https:\/\/drolin-box.com\/en\/mining-container-installation-checklist\/\">Lista de verificaci\u00f3n para la instalaci\u00f3n de contenedores mineros<\/a> antes de la entrega y la puesta en servicio.<\/p><p>M\u00e1s informaci\u00f3n sobre <a href=\"https:\/\/drolin-box.com\/en\/about\/services\/\">Servicios de planificaci\u00f3n de emplazamientos para granjas de miner\u00eda<\/a> o <a href=\"https:\/\/drolin-box.com\/en\/contact\/\">Ponte en contacto con DroLinBox<\/a> para enviar la informaci\u00f3n de tu proyecto.<\/p><h2>Veredicto final: Una planta lista para entrar en operaci\u00f3n tiene m\u00e1s valor que un megavatio sin utilizar<\/h2><p>Ni siquiera el mejor contenedor para miner\u00eda puede solucionar una conexi\u00f3n a la red el\u00e9ctrica deficiente, un transformador de capacidad insuficiente, cimientos inestables o una ruta de entrega a la que el cami\u00f3n no pueda acceder.<\/p><p>Una buena preparaci\u00f3n del sitio para una granja de miner\u00eda conecta todos los l\u00edmites del proyecto antes de que comience la fabricaci\u00f3n:<\/p><p><strong>Energ\u00eda \u2192 Contenedor \u2192 Refrigeraci\u00f3n \u2192 Cimientos \u2192 Log\u00edstica \u2192 Puesta en marcha<\/strong><\/p><p>Si se confirman esas interfaces desde el principio, el contenedor puede llegar como un activo de infraestructura modular.<\/p><p>Si los ignoras, el sitio gastar\u00e1 su presupuesto de implementaci\u00f3n en resolver problemas que se podr\u00edan haber evitado.<\/p><p>Primero prepara el lugar. Luego calcula el precio del contenedor.<\/p><h2>Preguntas frecuentes<\/h2><h3>\u00bfQu\u00e9 tipo de cimentaci\u00f3n necesita un contenedor para miner\u00eda?<\/h3><p>Los cimientos pueden consistir en una losa reforzada, vigas de nivelaci\u00f3n o pilares aislados, dependiendo de los puntos de apoyo del contenedor, el peso operativo, la capacidad portante del suelo, la profundidad de congelaci\u00f3n y las condiciones e\u00f3licas y s\u00edsmicas. Un ingeniero estructural debe dise\u00f1arlos a partir del plano de interfaz de cimientos proporcionado por el proveedor.<\/p><h3>\u00bfCu\u00e1nta capacidad de transformador necesita un contenedor minero?<\/h3><p>Calcula primero la carga de TI m\u00e1xima de los mineros y, a continuaci\u00f3n, incluye las cargas de enfriamiento y auxiliares mediante un modelo de carga de la instalaci\u00f3n o de PUE. Convierte los kW a kVA utilizando el factor de potencia esperado e incluye el objetivo de carga seleccionado, las condiciones ambientales, la altitud y los requisitos de redundancia.<\/p><h3>\u00bfSe puede instalar un contenedor para miner\u00eda directamente sobre grava compactada?<\/h3><p>Algunas configuraciones temporales pueden utilizar soportes de dise\u00f1o espec\u00edfico, pero no se debe dar por sentado que la grava compactada com\u00fan proporcione la nivelaci\u00f3n, el control de asentamiento, el anclaje o el drenaje adecuados. El proveedor y el ingeniero civil local deben aprobar el m\u00e9todo de soporte.<\/p><h3>\u00bfCu\u00e1nto espacio se necesita alrededor de un contenedor de miner\u00eda?<\/h3><p>No existe un espacio libre universal. El espacio depende del recorrido de las puertas, los espacios libres para el funcionamiento de los sistemas el\u00e9ctricos, el flujo de aire, la recirculaci\u00f3n de los gases de escape, el reemplazo de filtros, el mantenimiento de las tuber\u00edas, el acceso para casos de incendio y las normativas locales. El dise\u00f1o final debe basarse en las zonas de mantenimiento indicadas por el proveedor y en los requisitos de la normativa local.<\/p><h3>\u00bfQu\u00e9 informaci\u00f3n se necesita antes de solicitar un plano del sitio?<\/h3><p>Proporcione la ubicaci\u00f3n del proyecto, los modelos de los mineros, las cantidades, la potencia disponible, el voltaje, los datos clim\u00e1ticos, la altitud, las preferencias de refrigeraci\u00f3n, fotograf\u00edas del sitio, informaci\u00f3n sobre el acceso por carretera y un plano del sitio disponible.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>A flat plot and a nearby power line do not make a mining site deployable. The real test is whether the site can receive a loaded container, place it safely, energize it without overloading the electrical system, reject heat on the hottest design day, drain stormwater, support maintenance access and preserve an emergency route. Miss [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":5907,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[27,28],"tags":[249,250,251,252,247,248],"class_list":["post-5906","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","category-news","tag-asic-mining-site-requirements","tag-mining-container-foundation","tag-mining-container-installation-requirements","tag-mining-container-power-requirements","tag-mining-container-site-requirements","tag-mining-farm-site-preparation"],"blocksy_meta":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Mining Container Site Requirements Checklist<\/title>\n<meta name=\"description\" content=\"Check power, foundation, climate, drainage, fire access, delivery routes and utility interfaces before installing a mining container.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/drolin-box.com\/es_co\/lista-de-verificacion-de-los-requisitos-del-sitio-para-contenedores-de-mineria\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Optimizing Global Crypto Infrastructure: Next-Gen Mining Containers by DroLin Box\" \/>\n<meta property=\"og:description\" content=\"Discover why leading mining operations choose DroLin Box for reliable, high-efficiency infrastructure. See our latest 20ft &amp; 40ft configurations for Bitcoin 2026.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/drolin-box.com\/es_co\/lista-de-verificacion-de-los-requisitos-del-sitio-para-contenedores-de-mineria\/\" \/>\n<meta property=\"og:site_name\" content=\"DroLin Box - Crypto Mining Containers | Air-Cooled &amp; Liquid-Cooling Solutions PUE 1.06\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ndwndn.enwa\/\" \/>\n<meta property=\"article:published_time\" content=\"2026-08-19T02:21:33+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-19T02:25:47+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/drolin-box.com\/wp-content\/uploads\/2026\/08\/mining-container-site-requirements-checklist-banner-16x9-1-1024x576.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"576\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Tomato-CADRO\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tomato-CADRO\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"14 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/drolin-box.com\\\/mining-container-site-requirements-checklist\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/drolin-box.com\\\/mining-container-site-requirements-checklist\\\/\"},\"author\":{\"name\":\"Tomato-CADRO\",\"@id\":\"https:\\\/\\\/drolin-box.com\\\/#\\\/schema\\\/person\\\/f25a65b2b2f87eea36654b2da7badf99\"},\"headline\":\"Mining Container Site Requirements Checklist: Power, Foundation, Drainage and Delivery Access\",\"datePublished\":\"2026-08-19T02:21:33+00:00\",\"dateModified\":\"2026-08-19T02:25:47+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/drolin-box.com\\\/mining-container-site-requirements-checklist\\\/\"},\"wordCount\":2962,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/drolin-box.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/drolin-box.com\\\/mining-container-site-requirements-checklist\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/drolin-box.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/mining-container-site-requirements-checklist-banner-16x9-1.png\",\"keywords\":[\"ASIC mining site requirements\",\"mining container foundation\",\"mining container installation requirements\",\"mining container power requirements\",\"mining container site requirements\",\"mining farm site preparation\"],\"articleSection\":[\"Blog\",\"News\"],\"inLanguage\":\"es-CO\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/drolin-box.com\\\/mining-container-site-requirements-checklist\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/drolin-box.com\\\/mining-container-site-requirements-checklist\\\/\",\"url\":\"https:\\\/\\\/drolin-box.com\\\/mining-container-site-requirements-checklist\\\/\",\"name\":\"Mining Container Site Requirements Checklist\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/drolin-box.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/drolin-box.com\\\/mining-container-site-requirements-checklist\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/drolin-box.com\\\/mining-container-site-requirements-checklist\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/drolin-box.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/mining-container-site-requirements-checklist-banner-16x9-1.png\",\"datePublished\":\"2026-08-19T02:21:33+00:00\",\"dateModified\":\"2026-08-19T02:25:47+00:00\",\"description\":\"Check power, foundation, climate, drainage, fire access, delivery routes and utility interfaces before installing a mining container.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/drolin-box.com\\\/mining-container-site-requirements-checklist\\\/#breadcrumb\"},\"inLanguage\":\"es-CO\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/drolin-box.com\\\/mining-container-site-requirements-checklist\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es-CO\",\"@id\":\"https:\\\/\\\/drolin-box.com\\\/mining-container-site-requirements-checklist\\\/#primaryimage\",\"url\":\"https:\\\/\\\/drolin-box.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/mining-container-site-requirements-checklist-banner-16x9-1.png\",\"contentUrl\":\"https:\\\/\\\/drolin-box.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/mining-container-site-requirements-checklist-banner-16x9-1.png\",\"width\":1672,\"height\":941,\"caption\":\"Mining Container Site Requirements Checklist: Power, Foundation, Drainage and Delivery Access\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/drolin-box.com\\\/mining-container-site-requirements-checklist\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/drolin-box.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Mining Container Site Requirements Checklist: Power, Foundation, Drainage and Delivery Access\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/drolin-box.com\\\/#website\",\"url\":\"https:\\\/\\\/drolin-box.com\\\/\",\"name\":\"DroLin Box - Crypto Mining Containers | Air-Cooled & Liquid-Cooling Solutions PUE 1.06\",\"description\":\"Enterprise-Grade Hydro &amp; Air Mining Containers \u2013 PUE 1.06, 336+ ASIC Capacity, Global CE\\\/UL\\\/CSA Certified for Sustainable Farms\",\"publisher\":{\"@id\":\"https:\\\/\\\/drolin-box.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/drolin-box.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es-CO\"},{\"@type\":[\"Organization\",\"Place\"],\"@id\":\"https:\\\/\\\/drolin-box.com\\\/#organization\",\"name\":\"DroLin Box - Crypto Mining Containers | Air-Cooled & Liquid-Cooling Solutions PUE 1.06\",\"url\":\"https:\\\/\\\/drolin-box.com\\\/\",\"logo\":{\"@id\":\"https:\\\/\\\/drolin-box.com\\\/mining-container-site-requirements-checklist\\\/#local-main-organization-logo\"},\"image\":{\"@id\":\"https:\\\/\\\/drolin-box.com\\\/mining-container-site-requirements-checklist\\\/#local-main-organization-logo\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/ndwndn.enwa\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/--72464b3b8\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@DroLinBoxMining\"],\"telephone\":[],\"openingHoursSpecification\":[{\"@type\":\"OpeningHoursSpecification\",\"dayOfWeek\":[\"Monday\",\"Tuesday\",\"Wednesday\",\"Thursday\",\"Friday\",\"Saturday\",\"Sunday\"],\"opens\":\"09:00\",\"closes\":\"17:00\"}]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/drolin-box.com\\\/#\\\/schema\\\/person\\\/f25a65b2b2f87eea36654b2da7badf99\",\"name\":\"Tomato-CADRO\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es-CO\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bfef211b72781ebcee617d8c270120fafbdd7163ee0a22e58305d68830fc4c75?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bfef211b72781ebcee617d8c270120fafbdd7163ee0a22e58305d68830fc4c75?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bfef211b72781ebcee617d8c270120fafbdd7163ee0a22e58305d68830fc4c75?s=96&d=mm&r=g\",\"caption\":\"Tomato-CADRO\"},\"url\":\"https:\\\/\\\/drolin-box.com\\\/es_co\\\/author\\\/tomato-cadro\\\/\"},{\"@type\":\"ImageObject\",\"inLanguage\":\"es-CO\",\"@id\":\"https:\\\/\\\/drolin-box.com\\\/mining-container-site-requirements-checklist\\\/#local-main-organization-logo\",\"url\":\"https:\\\/\\\/drolin-box.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/drolinbox-logo-2.png\",\"contentUrl\":\"https:\\\/\\\/drolin-box.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/drolinbox-logo-2.png\",\"width\":190,\"height\":52,\"caption\":\"DroLin Box - Crypto Mining Containers | Air-Cooled & Liquid-Cooling Solutions PUE 1.06\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Lista de verificaci\u00f3n de los requisitos del sitio para contenedores mineros","description":"Antes de instalar un contenedor para miner\u00eda, verifica el suministro el\u00e9ctrico, los cimientos, las condiciones clim\u00e1ticas, el drenaje, el acceso para los bomberos, las rutas de entrega y las conexiones a los servicios p\u00fablicos.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/drolin-box.com\/es_co\/lista-de-verificacion-de-los-requisitos-del-sitio-para-contenedores-de-mineria\/","og_locale":"es_ES","og_type":"article","og_title":"Optimizing Global Crypto Infrastructure: Next-Gen Mining Containers by DroLin Box","og_description":"Discover why leading mining operations choose DroLin Box for reliable, high-efficiency infrastructure. See our latest 20ft & 40ft configurations for Bitcoin 2026.","og_url":"https:\/\/drolin-box.com\/es_co\/lista-de-verificacion-de-los-requisitos-del-sitio-para-contenedores-de-mineria\/","og_site_name":"DroLin Box - Crypto Mining Containers | Air-Cooled &amp; Liquid-Cooling Solutions PUE 1.06","article_publisher":"https:\/\/www.facebook.com\/ndwndn.enwa\/","article_published_time":"2026-08-19T02:21:33+00:00","article_modified_time":"2026-08-19T02:25:47+00:00","og_image":[{"width":1024,"height":576,"url":"https:\/\/drolin-box.com\/wp-content\/uploads\/2026\/08\/mining-container-site-requirements-checklist-banner-16x9-1-1024x576.png","type":"image\/png"}],"author":"Tomato-CADRO","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"Tomato-CADRO","Tiempo de lectura":"14 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/drolin-box.com\/mining-container-site-requirements-checklist\/#article","isPartOf":{"@id":"https:\/\/drolin-box.com\/mining-container-site-requirements-checklist\/"},"author":{"name":"Tomato-CADRO","@id":"https:\/\/drolin-box.com\/#\/schema\/person\/f25a65b2b2f87eea36654b2da7badf99"},"headline":"Mining Container Site Requirements Checklist: Power, Foundation, Drainage and Delivery Access","datePublished":"2026-08-19T02:21:33+00:00","dateModified":"2026-08-19T02:25:47+00:00","mainEntityOfPage":{"@id":"https:\/\/drolin-box.com\/mining-container-site-requirements-checklist\/"},"wordCount":2962,"commentCount":0,"publisher":{"@id":"https:\/\/drolin-box.com\/#organization"},"image":{"@id":"https:\/\/drolin-box.com\/mining-container-site-requirements-checklist\/#primaryimage"},"thumbnailUrl":"https:\/\/drolin-box.com\/wp-content\/uploads\/2026\/08\/mining-container-site-requirements-checklist-banner-16x9-1.png","keywords":["ASIC mining site requirements","mining container foundation","mining container installation requirements","mining container power requirements","mining container site requirements","mining farm site preparation"],"articleSection":["Blog","News"],"inLanguage":"es-CO","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/drolin-box.com\/mining-container-site-requirements-checklist\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/drolin-box.com\/mining-container-site-requirements-checklist\/","url":"https:\/\/drolin-box.com\/mining-container-site-requirements-checklist\/","name":"Lista de verificaci\u00f3n de los requisitos del sitio para contenedores mineros","isPartOf":{"@id":"https:\/\/drolin-box.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/drolin-box.com\/mining-container-site-requirements-checklist\/#primaryimage"},"image":{"@id":"https:\/\/drolin-box.com\/mining-container-site-requirements-checklist\/#primaryimage"},"thumbnailUrl":"https:\/\/drolin-box.com\/wp-content\/uploads\/2026\/08\/mining-container-site-requirements-checklist-banner-16x9-1.png","datePublished":"2026-08-19T02:21:33+00:00","dateModified":"2026-08-19T02:25:47+00:00","description":"Antes de instalar un contenedor para miner\u00eda, verifica el suministro el\u00e9ctrico, los cimientos, las condiciones clim\u00e1ticas, el drenaje, el acceso para los bomberos, las rutas de entrega y las conexiones a los servicios p\u00fablicos.","breadcrumb":{"@id":"https:\/\/drolin-box.com\/mining-container-site-requirements-checklist\/#breadcrumb"},"inLanguage":"es-CO","potentialAction":[{"@type":"ReadAction","target":["https:\/\/drolin-box.com\/mining-container-site-requirements-checklist\/"]}]},{"@type":"ImageObject","inLanguage":"es-CO","@id":"https:\/\/drolin-box.com\/mining-container-site-requirements-checklist\/#primaryimage","url":"https:\/\/drolin-box.com\/wp-content\/uploads\/2026\/08\/mining-container-site-requirements-checklist-banner-16x9-1.png","contentUrl":"https:\/\/drolin-box.com\/wp-content\/uploads\/2026\/08\/mining-container-site-requirements-checklist-banner-16x9-1.png","width":1672,"height":941,"caption":"Mining Container Site Requirements Checklist: Power, Foundation, Drainage and Delivery Access"},{"@type":"BreadcrumbList","@id":"https:\/\/drolin-box.com\/mining-container-site-requirements-checklist\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/drolin-box.com\/"},{"@type":"ListItem","position":2,"name":"Mining Container Site Requirements Checklist: Power, Foundation, Drainage and Delivery Access"}]},{"@type":"WebSite","@id":"https:\/\/drolin-box.com\/#website","url":"https:\/\/drolin-box.com\/","name":"DroLin Box - Contenedores para miner\u00eda de criptomonedas | Soluciones de enfriamiento por aire y por l\u00edquido, PUE 1,06","description":"Contenedores de miner\u00eda hidr\u00e1ulica y de aire de nivel empresarial: PUE de 1,06, capacidad para m\u00e1s de 336 ASIC, con certificaci\u00f3n global CE\/UL\/CSA para granjas sostenibles","publisher":{"@id":"https:\/\/drolin-box.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/drolin-box.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es-CO"},{"@type":["Organization","Place"],"@id":"https:\/\/drolin-box.com\/#organization","name":"DroLin Box - Contenedores para miner\u00eda de criptomonedas | Soluciones de enfriamiento por aire y por l\u00edquido, PUE 1,06","url":"https:\/\/drolin-box.com\/","logo":{"@id":"https:\/\/drolin-box.com\/mining-container-site-requirements-checklist\/#local-main-organization-logo"},"image":{"@id":"https:\/\/drolin-box.com\/mining-container-site-requirements-checklist\/#local-main-organization-logo"},"sameAs":["https:\/\/www.facebook.com\/ndwndn.enwa\/","https:\/\/www.linkedin.com\/in\/--72464b3b8\/","https:\/\/www.youtube.com\/@DroLinBoxMining"],"telephone":[],"openingHoursSpecification":[{"@type":"OpeningHoursSpecification","dayOfWeek":["Monday","Tuesday","Wednesday","Thursday","Friday","Saturday","Sunday"],"opens":"09:00","closes":"17:00"}]},{"@type":"Person","@id":"https:\/\/drolin-box.com\/#\/schema\/person\/f25a65b2b2f87eea36654b2da7badf99","name":"Tomate-CADRO","image":{"@type":"ImageObject","inLanguage":"es-CO","@id":"https:\/\/secure.gravatar.com\/avatar\/bfef211b72781ebcee617d8c270120fafbdd7163ee0a22e58305d68830fc4c75?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bfef211b72781ebcee617d8c270120fafbdd7163ee0a22e58305d68830fc4c75?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bfef211b72781ebcee617d8c270120fafbdd7163ee0a22e58305d68830fc4c75?s=96&d=mm&r=g","caption":"Tomato-CADRO"},"url":"https:\/\/drolin-box.com\/es_co\/author\/tomato-cadro\/"},{"@type":"ImageObject","inLanguage":"es-CO","@id":"https:\/\/drolin-box.com\/mining-container-site-requirements-checklist\/#local-main-organization-logo","url":"https:\/\/drolin-box.com\/wp-content\/uploads\/2026\/01\/drolinbox-logo-2.png","contentUrl":"https:\/\/drolin-box.com\/wp-content\/uploads\/2026\/01\/drolinbox-logo-2.png","width":190,"height":52,"caption":"DroLin Box - Crypto Mining Containers | Air-Cooled & Liquid-Cooling Solutions PUE 1.06"}]}},"_links":{"self":[{"href":"https:\/\/drolin-box.com\/es_co\/wp-json\/wp\/v2\/posts\/5906","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/drolin-box.com\/es_co\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/drolin-box.com\/es_co\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/drolin-box.com\/es_co\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/drolin-box.com\/es_co\/wp-json\/wp\/v2\/comments?post=5906"}],"version-history":[{"count":4,"href":"https:\/\/drolin-box.com\/es_co\/wp-json\/wp\/v2\/posts\/5906\/revisions"}],"predecessor-version":[{"id":5911,"href":"https:\/\/drolin-box.com\/es_co\/wp-json\/wp\/v2\/posts\/5906\/revisions\/5911"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/drolin-box.com\/es_co\/wp-json\/wp\/v2\/media\/5907"}],"wp:attachment":[{"href":"https:\/\/drolin-box.com\/es_co\/wp-json\/wp\/v2\/media?parent=5906"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/drolin-box.com\/es_co\/wp-json\/wp\/v2\/categories?post=5906"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/drolin-box.com\/es_co\/wp-json\/wp\/v2\/tags?post=5906"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}