logo-drolinbox-b

· INDUSTRAL COOLING SYSTEMS

Precision Liquid Cooling 

From 200kW to 1MW

 
Industrial-grade CDUs engineered for Bitcoin mining farms, high-density data 
centers, and containerized computing. Dual-redundant pumps, stainless steel 
heat exchangers, and intelligent controls — built to run continuously in extreme 
environments.

1MW

 

Max Cooling Capacity

≤55dB

Operating Noise Level

35°C

Stable Outlet Temperature

30+

Years Manufacturing Expertise

DROLIN BOX · INDUSTRIAL COOLING SYSTEMS

Precision Liquid Cooling 

From 200kW to 1MW

Industrial-grade CDUs engineered for Bitcoin mining farms, 
high-density datacenters, and containerized computing. 
Dual-redundant pumps, stainless steel heat exchangers, 
and intelligent controls — built to run continuously in 
extreme environments.

1MW

Max Cooling Capacity

≤55dB

Operating Noise Level

35°C

Stable Outlet Temperature

30+

Mfg Expertise Yrs

Үздік баға үшін бізбен байланысыңыз

Контакт формасының демосы

Дролин Бокс

CDU Models for Every Scale

Industrial-grade CDUs engineered for Bitcoin mining farms, high-density data centers, and containerized computing. Dual-redundant pumps, stainless steel heat exchangers, and intelligent controls — built to run continuously in extreme environments.

MODEL 01

200KW

Cooling Capacity
200 kW @25°C

Dimensions (CDU)

1000×1200×2200mm

Құрғақ салқындатқыш

Dual-pump, online swap

Noise Level

≤55 dB(A)

Pump Redundancy

Online replaceable

Heat Exchanger

SS304 Stainless Steel

MODEL 02

400KW

Cooling Capacity
400 kW @25°C

Dimensions (CDU)

1000×1200×2200mm

Құрғақ салқындатқыш

Dual redundant pumps

Noise Level

≤55 dB(A)

Pump Redundancy

Online replaceable

Heat Exchanger

SS304 Stainless Steel

MODEL 03

600KW

Cooling Capacity
600 kW @25°C

Dimensions (CDU)

1200×1200×2200mm

Құрғақ салқындатқыш

Dual redundant pumps

Noise Level

≤55 dB(A)

Pump Redundancy

Online replaceable

Heat Exchanger

SS304 Stainless Steel

MODEL 04

800KW

Cooling Capacity
800 kW @25°C

Dimensions (CDU)

1200×1200×2200mm

Құрғақ салқындатқыш

Dual redundant pumps

Noise Level

≤55 dB(A)

Pump Redundancy

Online replaceable

Heat Exchanger

SS304 Stainless Steel

MODEL 05

1MW

Cooling Capacity
1000 kW @25°C

Dimensions (CDU)

1400×1200×2200mm

Құрғақ салқындатқыш

Dual redundant pumps

Noise Level

≤55 dB(A)

Pump Redundancy

Online replaceable

Heat Exchanger

SS304 Stainless Steel

Engineering Built for Continuous Operation

Every DroLin CDU is designed around one principle: zero unplanned downtime. Dual redundancy, field-serviceable
components, and real-time monitoring come standard across the entire range.

01 — REDUNDANCY

N+1 Dual-Pump Architecture
Two fully independent pump loops run in parallel 
— one active, one on standby. If the primary 
pump fails, the backup activates instantly with no
interruption to cooling flow. Pumps are hot-swappable 
without shutting down the system.
 

02 — HEAT REJECTION

SS304 Stainless Steel Plate Heat Exchanger
High-efficiency plate-type heat exchangers manufactured
from 304-grade stainless steel provide superior corrosion
resistance and thermal performance. The secondary loop
stays fully isolated from facility water — protecting your
mining hardware from contamination.

03 — FILTRATION

Online-Replaceable Filter System
Proprietary filter cartridges can be replaced during live
operation without stopping coolant flow. No scheduled
maintenance windows required — service your filtration
system whenever needed, without affecting hashrate.

04 — TEMPERATURE CONTROL

Precision Outlet Temperature: 35°C ± 1°C
Integrated PLC-based control maintains outlet coolant 
temperature within ±1°C under varying ambient conditions
and load changes. Stable inlet temperatures directly translate
to stable hashrate and extended ASIC lifespan.

05 — ACOUSTIC DESIGN

≤55 dB(A) Noise Floor
Industrial-grade pump isolation mounts and vibration
dampening reduce operating noise to ≤55 dB(A) — 
well within commercial and warehouse deployment 
standards, enabling installation in noise-sensitive 
environments.
01 — REDUNDANCY 02 — HEAT REJECTION 03 — FILTRATION 04 — TEMPERATURE CONTROL 05 — ACOUSTIC DESIGN

CDU Models for Every Scale

Industrial-grade CDUs engineered for Bitcoin mining farms, high-density data centers, and containerized computing. Dual-redundant pumps, stainless steel heat exchangers, and intelligent controls — built to run continuously in extreme environments.

MODEL 01

200KW

 
Cooling Capacity
200 kW @25°C

Dimensions (CDU)

1000×1200×2200mm

Құрғақ салқындатқыш

Dual-pump, online swap

Noise Level

≤55 dB(A)

Pump Redundancy

Online replaceable

Heat Exchanger

SS304 Stainless Steel

MODEL 02

400KW

 
Cooling Capacity
400 kW @25°C

Dimensions (CDU)

1000×1200×2200mm

Құрғақ салқындатқыш

Dual redundant pumps

Noise Level

≤55 dB(A)

Pump Redundancy

Online replaceable

Heat Exchanger

SS304 Stainless Steel

MODEL 03

600KW

 
Cooling Capacity
600 kW @25°C

Dimensions (CDU)

1200×1200×2200mm

Құрғақ салқындатқыш

Dual redundant pumps

Noise Level

≤55 dB(A)

Pump Redundancy

Online replaceable

Heat Exchanger

SS304 Stainless Steel

MODEL 04

800KW

Cooling Capacity
800 kW @25°C

Dimensions (CDU)

1200×1200×2200mm

Құрғақ салқындатқыш

Dual redundant pumps

Noise Level

≤55 dB(A)

Pump Redundancy

Online replaceable

Heat Exchanger

SS304 Stainless Steel

MODEL 05

1MW

Cooling Capacity
1000 kW @25°C

Dimensions (CDU)

1400×1200×2200mm

Құрғақ салқындатқыш

Dual redundant pumps

Noise Level

≤55 dB(A)

Pump Redundancy

Online replaceable

Heat Exchanger

SS304 Stainless Steel

Engineering Built for 

Continuous Operation

 

Every DroLin CDU is designed around one principle: zero unplanned downtime. Dual redundancy, field-serviceable components, and real-time monitoring come standard across the entire range.

line

01 — REDUNDANCY

N+1 Dual-Pump Architecture

Two fully independent pump loops run in parallel — one active, one on standby. If the primary pump fails, the backup activates instantly with no interruption to cooling flow. Pumps are hot-swappable without shutting down the system.

line

02 — HEAT REJECTION

SS304 Stainless Steel Plate Heat Exchanger

High-efficiency plate-type heat exchangers manufactured from 304-grade stainless steel provide superior corrosion resistance and thermal performance. The secondary loop stays fully isolated from facility water — protecting your mining hardware from contamination.

line

03 — FILTRATION

Online-Replaceable Filter System

Proprietary filter cartridges can be replaced during live operation without stopping coolant flow. No scheduled maintenance windows required — service your filtration system whenever needed, without affecting hashrate.

line

04 — TEMPERATURE CONTROL

Precision Outlet Temperature: 35°C ± 1°C

Integrated PLC-based control maintains outlet coolant temperature within ±1°C under varying ambient conditions and load changes. Stable inlet temperatures directly translate to stable hashrate and extended ASIC lifespan.

line

05 — ACOUSTIC DESIGN

≤55 dB(A) Noise Floor

Industrial-grade pump isolation mounts and vibration dampening reduce operating noise to ≤55 dB(A) — well within commercial and warehouse deployment standards, enabling installation in noise-sensitive environments.

READY TO SCALE?

Get Your CDU Quoted

in 24 Hours


Tell us your power density, site conditions, and ASIC model — our engineering team

will size the right CDU and send a factory-direct quote within one business day.


READY TO SCALE?

Get Your CDU Quoted

in 24 Hours

 

Tell us your power density, site conditions, and ASIC model — our engineering teamwill size the right CDU and send a factory-direct quote within one business day.

 

Where DroLin CDUs Deploy

Designed to integrate into any liquid-cooled computing environment — from
containerized mining farms to enterprise data centers and hybrid energy sites.

Bitcoin Mining Farms

Pair with DroLin liquid cooling containers for end-to-end mining infrastructure. CDUs maintain stable 35°C coolant to Hydro ASICs — enabling sustained overclocking and maximum hashrate density per MW.

Containerized Data Centers

Drop-in CDU integration for 40HC and 45HC containerized computing deployments. Compact footprint fits within standard container dimensions. Ships pre-commissioned and ready to connect.

Renewable Energy Sites

Low-power CDU design pairs with solar and hydro-powered mining operations. Minimal auxiliary power draw ensures grid-independent sites maximize renewable energy utilization with PUE approaching 1.06.

Enterprise Colocation

Enterprise CDUs integrate directly into existing chilled water loops via facility connection ports. Support standard BACnet/Modbus building management protocols for full BMS integration.

HPC & AI Infrastructure

High rack density GPU servers generate 10–30kW per rack — beyond air cooling limits. DroLin CDUs maintain precise coolant temperatures for continuous HPC and AI training workloads.

Warehouse & Industrial Sites

Industrial-rated enclosures withstand dust, humidity, and wide temperature swings. IP54-rated CDU bodies are suitable for warehouse, semi-outdoor, and factory-floor mining deployments.

Where DroLin CDUs Deploy

 
Designed to integrate into any liquid-cooled computing environment — from
containerized mining farms to enterprise data centers and hybrid energy sites.

Bitcoin Mining Farms

Pair with DroLin liquid cooling containers for end-to-end mining infrastructure. CDUs maintain stable 35°C coolant to Hydro ASICs — enabling sustained overclocking and maximum hashrate density per MW.

Containerized Data Centers

Drop-in CDU integration for 40HC and 45HC containerized computing deployments. Compact footprint fits within standard container dimensions. Ships pre-commissioned and ready to connect.

Renewable Energy Sites

Low-power CDU design pairs with solar and hydro-powered mining operations. Minimal auxiliary power draw ensures grid-independent sites maximize renewable energy utilization with PUE approaching 1.06.

Enterprise Colocation

Enterprise CDUs integrate directly into existing chilled water loops via facility connection ports. Support standard BACnet/Modbus building management protocols for full BMS integration.

HPC & AI Infrastructure

High rack density GPU servers generate 10–30kW per rack — beyond air cooling limits. DroLin CDUs maintain precise coolant temperatures for continuous HPC and AI training workloads.

Warehouse & Industrial Sites

Industrial-rated enclosures withstand dust, humidity, and wide temperature swings. IP54-rated CDU bodies are suitable for warehouse, semi-outdoor, and factory-floor mining deployments.

Детальдардағы талғампаз дизайн

CDU detail 1
CDU detail 2
CDU detail 3
CDU detail 4
CDU detail 5

Детальдардағы талғампаз дизайн

CDU detail 1
CDU detail 4
CDU detail 3
CDU detail 5
CDU detail 2

Жиі қойылатын сұрақтар

Салқындатқыш тарату құрылғысы (CDU) дегеніміз не және ол қалай жұмыс істейді?

A CDU is the central thermal management unit in a liquid cooling system. It circulates coolant between your IT equipment (miners or servers) and the facility’s heat rejection system (dry cooler or cooling tower). The CDU maintains a clean, closed secondary loop — keeping your hardware isolated from facility water and controlling coolant temperature, pressure, and flow rate automatically.

Мен тау-кен фермам үшін қандай қуаттылығы бар CDU қажет?

Жалпы ASIC қуатын есептеп, 20% қосымша резерв қосыңыз. Мысалы, 200 дана Antminer S21 Hydro (әрқайсысы 5 360 Вт) = 1 072 кВт жалпы — жеткілікті резерві бар 1 МВт CDU. Біздің инженерлік командамыз 500 кВт-тан асатын кез келген жобаға сыйымдылықты анықтау бойынша тегін кеңес береді.

DroLin CDU-лары Antminer S19/S21 Hydro және Whatsminer M56-пен үйлесімді ме?

Иә. Барлық DroLin CDU-лары Bitmain Antminer S19/S21 Hydro серияларымен, MicroBT Whatsminer M56/M30/M50 серияларымен және Canaan Avalon Hydro майнерлерімен толық үйлесімді. 35 °C ±1 °C салқындатқыш шығыс температурасы барлық ірі ASIC брендтерінің өндірушілерінің техникалық сипаттамаларына сәйкес келеді.

DroLin CDU-лары қандай салқындатқыш түрлерін қолдайды?

Стандартты конфигурация тазартылған (ионсыздандырылған) су мен су-гликол қоспаларын -20°C-қа дейінгі сыртқы температурада суық климатта қолдануға қолдайды. Сондай-ақ арнайы қолданбалар үшін салқындатқыш сұйықтықтың жекелеген сипаттамаларын да ұсынамыз — сіздің нысаныңыздағы коррозияға қарсы ингибиторларға қойылатын талаптарды талқылау үшін бізбен байланысыңыз.

Тапсырыстан жеткізуге дейінгі мерзім қанша?

Стандартты модельдер (200 кВт–1 МВт) тапсырыс расталғаннан кейін 15–25 жұмыс күні ішінде жөнелтіледі. Жекешелендірілген конфигурациялар немесе ірі көлемді тапсырыстар: 30–45 күн. Барлық бірліктер біздің Ханчжоу зауытынан алдын ала іске қосылып, толық сынақ есептерімен бірге жөнелтіледі.

CDU-ларға орындағы құрғақ салқындатқыш немесе салқындату мұнарасы қажет пе?

CDU негізгі (объектілік) жағында жылуды шығару блогын қажет етеді. 100 кВт модельге құрғақ салқындатқыш кіреді. Үлкенірек модельдер (200 кВт–1 МВт) сәйкес өлшемдегі бөлек құрғақ салқындатқыш немесе салқындату мұнарасын талап етеді — біз оларды толық салқындату шешімінің құрамында жеткіземіз және сіздің климатыңыз бен орналасқан жеріңізге сәйкес дұрыс құрылғыны таңдауға көмектесеміз.

Байланысайық

DroLin Box-тағы біздің арнайы командамыз жобаңызды талқылауға дайын – бастапқы бағалаудан толық енгізуге дейін.

Бос форма (#4)

Байланысайық

DroLin Box-тағы біздің арнайы командамыз жобаңызды талқылауға дайын – бастапқы бағалаудан толық енгізуге дейін.

Бос форма (#4)
Бос форма (#5)