· INDUSTRAL COOLING SYSTEMS
Precision Liquid Cooling
From 200kW to 1MW
1MW
Max Cooling Capacity
≤55dB
Operating Noise Level
35°C
Stable Outlet Temperature
30+
Years Manufacturing Expertise
DROLIN BOX · INDUSTRIAL COOLING SYSTEMS
Precision Liquid Cooling
From 200kW to 1MW
1MW
Max Cooling Capacity
≤55dB
Operating Noise Level
35°C
Stable Outlet Temperature
30+
Mfg Expertise Yrs
Contact Us for the Best Price
صندوق درولين
CDU Models for Every Scale
Industrial-grade CDUs engineered for Bitcoin mining farms, high-density data centers, and containerized computing. Dual-redundant pumps, stainless steel heat exchangers, and intelligent controls — built to run continuously in extreme environments.
MODEL 01
200KW
|
Cooling Capacity
|
200 kW @25°C
|
Dimensions (CDU) |
1000×1200×2200mm |
|---|---|
|
Dry Cooler |
Dual-pump, online swap |
|
Noise Level |
≤55 dB(A) |
|
Pump Redundancy |
Online replaceable |
|
Heat Exchanger |
SS304 Stainless Steel |
MODEL 02
400KW
|
Cooling Capacity
|
400 kW @25°C
|
Dimensions (CDU) |
1000×1200×2200mm |
|---|---|
|
Dry Cooler |
Dual redundant pumps |
|
Noise Level |
≤55 dB(A) |
|
Pump Redundancy |
Online replaceable |
|
Heat Exchanger |
SS304 Stainless Steel |
MODEL 03
600KW
|
Cooling Capacity
|
600 kW @25°C
|
Dimensions (CDU) |
1200×1200×2200mm |
|---|---|
|
Dry Cooler |
Dual redundant pumps |
|
Noise Level |
≤55 dB(A) |
|
Pump Redundancy |
Online replaceable |
|
Heat Exchanger |
SS304 Stainless Steel |
MODEL 04
800KW
|
Cooling Capacity
|
800 kW @25°C
|
Dimensions (CDU) |
1200×1200×2200mm |
|---|---|
|
Dry Cooler |
Dual redundant pumps |
|
Noise Level |
≤55 dB(A) |
|
Pump Redundancy |
Online replaceable |
|
Heat Exchanger |
SS304 Stainless Steel |
MODEL 05
1MW
|
Cooling Capacity
|
1000 kW @25°C
|
Dimensions (CDU) |
1400×1200×2200mm |
|---|---|
|
Dry Cooler |
Dual redundant pumps |
|
Noise Level |
≤55 dB(A) |
|
Pump Redundancy |
Online replaceable |
|
Heat Exchanger |
SS304 Stainless Steel |
Engineering Built for Continuous Operation
Every DroLin CDU is designed around one principle: zero unplanned downtime. Dual redundancy, field-serviceable components, and real-time monitoring come standard across the entire range.
01 — REDUNDANCY
02 — HEAT REJECTION
03 — FILTRATION
04 — TEMPERATURE CONTROL
05 — ACOUSTIC DESIGN
CDU Models for Every Scale
Industrial-grade CDUs engineered for Bitcoin mining farms, high-density data centers, and containerized computing. Dual-redundant pumps, stainless steel heat exchangers, and intelligent controls — built to run continuously in extreme environments.
MODEL 01
200KW
|
Cooling Capacity
|
200 kW @25°C
|
Dimensions (CDU) |
1000×1200×2200mm |
|---|---|
|
Dry Cooler |
Dual-pump, online swap |
|
Noise Level |
≤55 dB(A) |
|
Pump Redundancy |
Online replaceable |
|
Heat Exchanger |
SS304 Stainless Steel |
MODEL 02
400KW
|
Cooling Capacity
|
400 kW @25°C
|
Dimensions (CDU) |
1000×1200×2200mm |
|---|---|
|
Dry Cooler |
Dual redundant pumps |
|
Noise Level |
≤55 dB(A) |
|
Pump Redundancy |
Online replaceable |
|
Heat Exchanger |
SS304 Stainless Steel |
MODEL 03
600KW
|
Cooling Capacity
|
600 kW @25°C
|
Dimensions (CDU) |
1200×1200×2200mm |
|---|---|
|
Dry Cooler |
Dual redundant pumps |
|
Noise Level |
≤55 dB(A) |
|
Pump Redundancy |
Online replaceable |
|
Heat Exchanger |
SS304 Stainless Steel |
MODEL 04
800KW
|
Cooling Capacity
|
800 kW @25°C
|
Dimensions (CDU) |
1200×1200×2200mm |
|---|---|
|
Dry Cooler |
Dual redundant pumps |
|
Noise Level |
≤55 dB(A) |
|
Pump Redundancy |
Online replaceable |
|
Heat Exchanger |
SS304 Stainless Steel |
MODEL 05
1MW
|
Cooling Capacity
|
1000 kW @25°C
|
Dimensions (CDU) |
1400×1200×2200mm |
|---|---|
|
Dry Cooler |
Dual redundant pumps |
|
Noise Level |
≤55 dB(A) |
|
Pump Redundancy |
Online replaceable |
|
Heat Exchanger |
SS304 Stainless Steel |
Engineering Built for
Continuous Operation
Every DroLin CDU is designed around one principle: zero unplanned downtime. Dual redundancy, field-serviceable components, and real-time monitoring come standard across the entire range.
01 — REDUNDANCY
N+1 Dual-Pump Architecture
Two fully independent pump loops run in parallel — one active, one on standby. If the primary pump fails, the backup activates instantly with no interruption to cooling flow. Pumps are hot-swappable without shutting down the system.
02 — HEAT REJECTION
SS304 Stainless Steel Plate Heat Exchanger
High-efficiency plate-type heat exchangers manufactured from 304-grade stainless steel provide superior corrosion resistance and thermal performance. The secondary loop stays fully isolated from facility water — protecting your mining hardware from contamination.
03 — FILTRATION
Online-Replaceable Filter System
Proprietary filter cartridges can be replaced during live operation without stopping coolant flow. No scheduled maintenance windows required — service your filtration system whenever needed, without affecting hashrate.
04 — TEMPERATURE CONTROL
Precision Outlet Temperature: 35°C ± 1°C
Integrated PLC-based control maintains outlet coolant temperature within ±1°C under varying ambient conditions and load changes. Stable inlet temperatures directly translate to stable hashrate and extended ASIC lifespan.
05 — ACOUSTIC DESIGN
≤55 dB(A) Noise Floor
Industrial-grade pump isolation mounts and vibration dampening reduce operating noise to ≤55 dB(A) — well within commercial and warehouse deployment standards, enabling installation in noise-sensitive environments.
READY TO SCALE?
Get Your CDU Quoted
in 24 Hours
Tell us your power density, site conditions, and ASIC model — our engineering team
will size the right CDU and send a factory-direct quote within one business day.
READY TO SCALE?
Get Your CDU Quoted
in 24 Hours
Tell us your power density, site conditions, and ASIC model — our engineering teamwill size the right CDU and send a factory-direct quote within one business day.
Where DroLin CDUs Deploy
Bitcoin Mining Farms
Pair with DroLin liquid cooling containers for end-to-end mining infrastructure. CDUs maintain stable 35°C coolant to Hydro ASICs — enabling sustained overclocking and maximum hashrate density per MW.
Containerized Data Centers
Drop-in CDU integration for 40HC and 45HC containerized computing deployments. Compact footprint fits within standard container dimensions. Ships pre-commissioned and ready to connect.
Renewable Energy Sites
Low-power CDU design pairs with solar and hydro-powered mining operations. Minimal auxiliary power draw ensures grid-independent sites maximize renewable energy utilization with PUE approaching 1.06.
Enterprise Colocation
Enterprise CDUs integrate directly into existing chilled water loops via facility connection ports. Support standard BACnet/Modbus building management protocols for full BMS integration.
HPC & AI Infrastructure
High rack density GPU servers generate 10–30kW per rack — beyond air cooling limits. DroLin CDUs maintain precise coolant temperatures for continuous HPC and AI training workloads.
Warehouse & Industrial Sites
Industrial-rated enclosures withstand dust, humidity, and wide temperature swings. IP54-rated CDU bodies are suitable for warehouse, semi-outdoor, and factory-floor mining deployments.
Where DroLin CDUs Deploy
Bitcoin Mining Farms
Pair with DroLin liquid cooling containers for end-to-end mining infrastructure. CDUs maintain stable 35°C coolant to Hydro ASICs — enabling sustained overclocking and maximum hashrate density per MW.
Containerized Data Centers
Drop-in CDU integration for 40HC and 45HC containerized computing deployments. Compact footprint fits within standard container dimensions. Ships pre-commissioned and ready to connect.
Renewable Energy Sites
Low-power CDU design pairs with solar and hydro-powered mining operations. Minimal auxiliary power draw ensures grid-independent sites maximize renewable energy utilization with PUE approaching 1.06.
Enterprise Colocation
Enterprise CDUs integrate directly into existing chilled water loops via facility connection ports. Support standard BACnet/Modbus building management protocols for full BMS integration.
HPC & AI Infrastructure
High rack density GPU servers generate 10–30kW per rack — beyond air cooling limits. DroLin CDUs maintain precise coolant temperatures for continuous HPC and AI training workloads.
Warehouse & Industrial Sites
Industrial-rated enclosures withstand dust, humidity, and wide temperature swings. IP54-rated CDU bodies are suitable for warehouse, semi-outdoor, and factory-floor mining deployments.
FAQ
ما هي وحدة توزيع سائل التبريد (CDU) وكيف تعمل؟
A CDU is the central thermal management unit in a liquid cooling system. It circulates coolant between your IT equipment (miners or servers) and the facility’s heat rejection system (dry cooler or cooling tower). The CDU maintains a clean, closed secondary loop — keeping your hardware isolated from facility water and controlling coolant temperature, pressure, and flow rate automatically.
ما هي سعة وحدة CDU التي أحتاجها لمزرعة التعدين الخاصة بي؟
احسب إجمالي استهلاك الطاقة لوحدات ASIC الخاصة بك وأضف هامشًا يبلغ 20%. على سبيل المثال، 200 × Antminer S21 Hydro (5,360 واط لكل وحدة) = إجمالي 1,072 كيلوواط — وحدة توزيع الطاقة (CDU) بقدرة 1 ميجاواط مع هامش كافٍ. يقدم فريقنا الهندسي استشارات مجانية لتحديد السعة المناسبة لأي مشروع تزيد طاقته عن 500 كيلوواط.
هل وحدات CDU من DroLin متوافقة مع أجهزة Antminer S19/S21 Hydro و Whatsminer M56؟
نعم. جميع وحدات توزيع الطاقة (CDU) من DroLin متوافقة تمامًا مع سلسلة Bitmain Antminer S19/S21 Hydro، وسلسلة MicroBT Whatsminer M56/M30/M50، وأجهزة التعدين Canaan Avalon Hydro. وتبلغ درجة حرارة مخرج سائل التبريد 35 درجة مئوية ±1 درجة مئوية، وهو ما يتوافق مع مواصفات الشركات المصنعة لجميع العلامات التجارية الكبرى لأجهزة ASIC.
ما هي أنواع سوائل التبريد التي تدعمها وحدات التحكم الرقمية (CDU) من DroLin؟
يدعم التكوين القياسي استخدام الماء النقي (المُزيل الأيونات) ومخاليط الماء والجليكول في عمليات التشغيل في المناخات الباردة حتى درجة حرارة محيطة تصل إلى -20 درجة مئوية. كما ندعم مواصفات سوائل التبريد المخصصة للتطبيقات الخاصة — يرجى الاتصال بنا لمناقشة متطلبات مثبطات التآكل الخاصة بموقعكم.
ما هي المدة الزمنية من تاريخ الطلب حتى التسليم؟
يتم شحن الطرازات القياسية (200 كيلوواط – 1 ميجاواط) في غضون 15–25 يوم عمل من تاريخ تأكيد الطلب. أما التكوينات المخصصة أو الطلبات ذات الكميات الكبيرة، فتستغرق 30–45 يومًا. يتم شحن جميع الوحدات بعد إجراء الاختبارات الأولية في مصنعنا في هانغتشو، مع تضمين تقارير الاختبار الكاملة.
هل تتطلب وحدات CDU وجود مبرد جاف أو برج تبريد في الموقع؟
تتطلب وحدة CDU وجود وحدة لتصريف الحرارة على الجانب الأساسي (المنشأة). ويشتمل الطراز الذي تبلغ قدرته 100 كيلوواط على مبرد جاف. أما الطرز الأكبر حجمًا (200 كيلوواط – 1 ميجاواط) فتتطلب مبردًا جافًا منفصلاً أو برج تبريد بحجم مناسب — ونحن نوفر هذه المكونات كجزء من حل تبريد متكامل، ويمكننا مساعدتك في تحديد الوحدة المناسبة لمناخك وموقعك.
LET'S CONNECT
Our dedicated team at DroLin Box is ready to discuss your project – from initial assessment to full deployment.
LET'S CONNECT
Our dedicated team at DroLin Box is ready to discuss your project – from initial assessment to full deployment.